1-20

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

Components of an Event Message

Time/date Severity

05/23/04 05:55:30 C sysmon[63]: Disk drive at enclosure 1 row 0 column 2
failed.

Facility FID Message body

■

Time/date- Time and Date of the event

■

Severity- Severity can be one of those listed below

■

Facility- The system module that reported the message

■

FID- The kernel ID of the Facility

■

Message Body- The contents of the message

Severity Level Definitions (highest to lowest)

■

Emergency—Specifies emergency messages. These messages are not distributed
to all users. Emergency priority messages are logged into a separate file for
reviewing.

■

Alert—Specifies important messages that require immediate attention. These
messages are distributed to all users.

■

Critical—Specifies critical messages not classified as errors, such as hardware
problems. Critical and higher-priority messages are sent to the system console.

■

Error—Specifies any messages that represent error conditions, such as an
unsuccessful disk write.

■

Warning—Specifies any messages for abnormal, but recoverable, conditions.

■

Notice—Specifies important informational messages. Messages without a priority
designation are mapped into this priority message.

■

Information—Specifies informational messages. These messages are useful in
analyzing the system.

■

Debug—Specifies debugging messages.

1.6.5

Error Codes from the Sun StorEdge 5310 NAS
LCD Display and syslog

This section details the specific error messages sent through e-mail, SNMP
notification, the LCD panel, and the system log to notify the administrator in the
event of a system error. SysMon, the monitoring thread in the Sun StorEdge 5310