Ups subsystem errors, Ups subsystem errors 22, Table a-3 – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 40: Ups error

Advertising
background image

1-22

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

UPS Subsystem Errors

Refer to Table A-3 for descriptions of UPS error conditions.

TABLE A-3

UPS Error Messages

Event

E-Mail Subject: Text

SNMP Trap

LCD Panel

Log

Power Failure

AC Power Failure:
AC power failure. System is running
on UPS battery.
Action: Restore system power.
Severity = Error

EnvUpsOn
Battery

U20 on
battery

UPS: AC power
failure. System is
running on UPS
battery.

Power Restored

AC power restored:
AC power restored. System is running
on AC power.
Severity = Notice

EnvUpsOff
Battery

U21 power
restored

UPS: AC power
restored.

Low Battery

UPS battery low:
UPS battery is low. The system will
shut down if AC power is not restored
soon.
Action: Restore AC power as soon as
possible.
Severity = Critical

EnvUpsLow
Battery

U22 low
battery

UPS: Low battery
condition.

Normal Battery

UPS battery recharged:
The UPS battery has been recharged.
Severity = Notice

EnvUps
Normal
Battery

U22 battery
normal

UPS: Battery
recharged to
normal condition.

Replace Battery

Replace UPS Battery:
The UPS battery is faulty.
Action: Replace the battery.
Severity = Notice

EnvUps
Replace
Battery

U23 battery
fault

UPS: Battery
requires
replacement.

UPS Alarms -
Ambient
temperature or
humidity
outside
acceptable
thresholds

UPS abnormal temperature/humidity:
Abnormal temperature/humidity
detected in the system.
Action: 1. Check UPS unit installation,
OR
2. Contact technical support.
Severity = Error

EnvUps
Abnormal

U24
abnormal
ambient

UPS: Abnormal
temperature
and/or humidity
detected.