7-36

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

23. After 24 hours, check the host link, drive link, fault, and battery lights to ensure

the battery is working properly. Figure 7-20 shows the locations of these lights. If
the battery has a fault, use the storage management software to check the
command module status and obtain the recovery procedure.

End Of Procedure

FIGURE 7-20

Drive Link, Host Link, Battery, and Fault Lights

7.7.3

Replacing a Drive

Use the following procedure to replace a drive in a command module. Figure 7-21
illustrates inserting and removing a drive.

7.7.3.1

Tools and Equipment

Antistatic protection

Replacement drive

7.7.3.2

Procedure

Caution –

Potential data loss or data corruption. Never insert drives into a drive

module without first confirming the drive firmware level. Inserting a drive with the
incorrect firmware level may cause data loss or data corruption. For information on
supported drive firmware levels, contact technical support.