5 high profile riser pci cards, High profile riser pci cards 12 – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 348

Advertising
background image

7-12

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

7.6.5

High Profile Riser PCI Cards

Note –

Add-in cards must be replaced while the riser board is removed from the

chassis.

The server supports 3V only and Universal PCI cards. It does not support 5V only
cards.

Caution –

Before touching or replacing any component inside the Sun StorEdge

5310 NAS, disconnect all external cables and follow the instructions in “Safety:
Before You Remove the Cover” on page 7-2 and “Removing and Replacing the
Cover” on page 7-2. Alway
s place the server on a grounded ESD pad and wear a
properly grounded antistatic wrist strap.

To replace a PCI card, follow these steps:

1. Before removing the cover to work inside the system, observe the previously

stated safety guidelines.

2. Remove the chassis cover.

3. Insert your finger in the plastic loop on the PCI riser assembly.

4. Pull straight up and remove the riser assembly from the chassis.

5. Open the retainer clip on the riser card retention bracket.

6. Pull the PCI card out of the riser board slot.

7. Install the new PCI add-in card on the riser assembly.

8. Insert the riser assembly connector in the server board slot while aligning the tabs

on the rear retention bracket with the holes in the chassis.

9. Firmly press the riser assembly straight down until it is seated in the server board

slot.

10. Replace the chassis cover if you have no additional work to do inside the chassis.

Advertising