Table 2-12, Bios-ge – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 74

Advertising
background image

2-28

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

2-1-2-3

Check ROM copyright notice.

2-2-3-1

Test for unexpected interrupts.

1-5-1-1

FRB failure (processor failure)

1-5-2-2

No processors installed or processor socket 1 is empty

1-5-2-3

Processor configuration error (for example, mismatched VIDs)

1-5-2-4

Front-side bus select configuration error (for example, mismatched BSELs)

1-5-4-2

Power fault: DC power unexpectedly lost (for example, power good from the
power supply was deasserted)

1-5-4-3

Chipset control failure

1-5-4-4

Power control failure (for example, power good from the power supply did
not respond to power request)

1 The code indicates the beep sequence; for example, 1-5-1-1 means a single beep, then a

pause, then 5 beeps in a row, then a pause, then a single beep, then a pause, and then
finally a single beep.

TABLE 2-12

BIOS-Generated Boot Block POST Beep Codes

Beep
Code

Error Message

Description

1

Refresh timer failure

The memory refresh circuitry on the motherboard is faulty.

2

Parity error

Parity can not be reset

3

Base memory failure

Base memory test failure. See Table 2-13 on page 2-29 for
additional error details.

4

System timer

System timer is not operational

5

Processor failure

Processor failure detected

6

Keyboard controller Gate A20
failure

The keyboard controller may be bad. The BIOS cannot switch
to protected mode.

7

Processor exception interrupt error

The CPU generated an exception interrupt.

8

Display memory read/write error

The system video adapter is either missing or its memory is
faulty. This is not a fatal error.

9

ROM checksum error

System BIOS ROM checksum error

10

Shutdown register error

Shutdown CMOS register read/write error detected

11

Invalid BIOS

General BIOS ROM error

TABLE 2-11

BMC-Generated POST Beep Codes

Beep Code

1

Description