File system errors, Pems events, File system errors 24 – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 42: Pems events 24, Table a-4, Table a-5

Advertising
background image

1-24

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

File System Errors

File system error messages occur when the file system usage exceeds a defined usage
threshold. The default usage threshold is 95%.

PEMS Events

Sun StorEdge 5310 NAS employs the PEMS board to monitor environmental systems
and to send messages regarding fan, power supply, and temperature anomalies.

Note –

Device locations are shown in the Sun StorEdge 5310 NAS Hardware

Installation, Configuration, and User Guide included in your documentation CD.

Table A-5 describes the PEMS error messages for the Sun StorEdge 5310 NAS.

TABLE A-4

File System Errors

Event

E-Mail Subject: Text

SNMP Trap

LCD Panel

Log

File System
Full

File system full:
File system <name> is xx% full.
Action: 1. Delete any unused or
temporary files, OR
2. Extend the partition by using an
unused partition, OR
3. Add additional disk drives and
extend the partition after creating a
new partition.
(Severity=Error)

PartitionFull

F40
FileSystemName
full

File system
<name> usage
capacity is xx%.

TABLE A-5

PEMS Error Messages

Event

E-Mail Subject: Text

SNMP Trap

LCD Panel

Log

CPU Fan
Error

Fan Failure:
The CPU fan has failed. Fan speed = xx
RPM.
Action: The system will shut down in 10
seconds to protect the CPU from damage.
You should replace the CPU fan before
turning the system back on.
Severity = Critical

envFanFail trap

P11 CPU fan
failed

The CPU fan
has failed!
Better shut
down.

Advertising