Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 43

Advertising
background image

Chapter 1

Troubleshooting Overview

1-25

Fan Error

Fan Failure:
Blower fan xx has failed. Fan speed = xx
RPM.
Action: The fan must be replaced as soon
as possible. If the temperature begins to
rise, the situation could become critical.
Severity = Error

envFanFail trap

P11 Fan xx
failed

Blower fan
xx has failed!

Power
Supply
Module
Failure

Power supply failure:
The power supply unit xx has failed.
Action: The power supply unit must be
replaced as soon as possible. Severity =
Error

envPowerFail
trap

P12 Power
xx failed

Power
supply unit
xx has failed.

Power
Supply
Module
Temperature

Power supply temperature critical:
The power supply unit xx is overheating.
Action: Replace the power supply to
avoid any permanent damage. Severity =
Critical

envPowerTemp
Critical trap

P22 Power
xx
overheated

Power
supply unit
xx is
overheating.

Temperature
Error

Temperature critical:
Temperature in the system is critical. It is
xxx Degrees Celsius.
Action: 1. Check for any fan failures, OR
2. Check for blockage of the ventilation,
OR
3. Move the system to a cooler place.
Severity = Error

envTemperatue
Error trap

P51 Temp
error

The
temperature
is critical.

Primary
Power Cord
Failure

Power cord failure:
The primary power cord has failed or
been disconnected.
Action: 1. Check the power cord
connections at both ends, OR
2. Replace the power cord.
Severity = Error

envPrimary
PowerFail trap

P31 Fail
PWR cord 1

The primary
power cord
has failed.

Secondary
Power Cord
Failure

Power cord failure:
The secondary power cord has failed or
been disconnected.
Action: 1. Check the power cord
connections at both ends, OR
2. Replace the power cord.
Severity = Error

envSecondary
PowerFail trap

P32 Fail
PWR cord 2

The
secondary
power cord
has failed.

TABLE A-5

PEMS Error Messages

Event

E-Mail Subject: Text

SNMP Trap

LCD Panel

Log

Advertising