Chapter 3

Storage Arrays

3-23

No - You are finished with this procedure. If you are still experiencing a problem
with this storage array, go to step 10.

7. Remove the cover.

8. If needed, turn off the alarm.

9. Check all of the lights on the front and the back of each module. Figure 3-14 and

Figure 3-15 show the locations of indicator lights. Table 3-2 and Table 3-3 refer you
to the appropriate procedures for various fault indicators. Go to the page
indicated in the tables, and perform the procedure for replacing any failed
component as needed.

10. If you are still experiencing a problem with this storage array, create, save, and

print a storage array profile, and then call technical support for assistance.

The storage array profile may be helpful when troubleshooting.

End of Procedure

FIGURE 3-14

Lights on the Front of a Command Module

TABLE 3-2

Lights on the Front of a Command Module

Location

Component
Light

Color

Normal Status

Problem
Status

Procedure

Drives

1

Drive
Active

Green

On, not flashing - no
data is being processed
Flashing - data is being
processed

Off

“Replacing
a Drive”
on page 7-
36

2

Drive Fault

Amber

Off
Flashing - drive, volume,
or storage array locate
function On, not flashing

On, not
flashing