2 procedure – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 360

Advertising
background image

7-24

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

7.7.1.2

Procedure

1. If needed, use the storage management software to create, save, and print a new

storage array profile.

2. Did the Recovery Guru direct you to replace a failed controller?

Yes - Go to step 3.

No - Run the Recovery Guru to identify the failed component. Go to step 3.

3. Remove the back cover.

4. If needed, turn off the alarm.

Caution –

Electrostatic discharge damage to sensitive components. To prevent

electrostatic discharge damage to the module, use proper antistatic protection when
handling the module components.

5. Put on antistatic protection.

6. Unpack the new controller.

Set the new controller on a dry, level surface. Save all packing materials in case you
need to return the controller.

7. Check the Fault lights to locate the failed controller. On the failed controller, the

amber fault light will be illuminated. Figure 7-9 shows the location of the fault
light.

Caution –

Potential data loss or degraded performance. To prevent data loss or

damage to a cable, do not twist, fold, pinch, or step on a fibre optic cable, and do not
bend a cable tighter than a 2-inch radius.