Table 2-10, Exte – Sun Microsystems SUN STOREDGETM 5310 NAS User Manual

Page 72

Advertising
background image

2-26

Sun StorEdge 5310 NAS Troubleshooting Guide • December 2004

TABLE 2-10

Extended POST Error Messages and Codes

Error Code

Error Message

Pause On Boot

8100

Processor 1 failed BIST

No

8101

Processor 2 failed BIST

No

8110

Processor 1 internal error (IERR)

No

8111

Processor 2 internal error (IERR)

No

8120

Processor 1 thermal trip error

No

8121

Processor 2 thermal trip error

No

8130

Processor 1 disabled

No

8131

Processor 2 disabled

No

8140

Processor 1 failed FRB-3 timer

No

8141

Processor 2 failed FRB-3 timer

No

8150

Processor 1 failed initialization on last boot.

No

8151

Processor 2 failed initialization on last boot.

No

8160

Processor 01: unable to apply BIOS update

Yes

8161

Processor 02: unable to apply BIOS update

Yes

8170

Processor P1 :L2 cache failed

Yes

8171

Processor P2 :L2 cache failed

Yes

8180

BIOS does not support current stepping for Processor P1

Yes

8181

BIOS does not support current stepping for Processor P2

Yes

8190

Watchdog timer failed on last boot

No

8191

4:1 core to bus ratio: processor cache disabled

Yes

8192

L2 Cache size mismatch

Yes

8193

CPUID, processor stepping are different

Yes

8194

CPUID, processor family are different

Yes

8195

Front side bus speed mismatch: System halted

Yes, Halt

8196

Processor models are different

Yes

8197

CPU speed mismatch

Yes

8198

Failed to load processor microcode

Yes

8300

Baseboard Management Controller (BMC) failed to function

Yes

8301

Front panel controller failed to function

Yes