SNMP C

OMMANDS

4-135

Example
This example shows the default engine ID.

snmp-server view

This command adds an SNMP view which controls user access to the
MIB. Use the no form to remove an SNMP view.

Syntax

snmp-server view view-name oid-tree {included | excluded}
no snmp-server view view-name

view-name - Name of an SNMP view. (Range: 1-64 characters)
oid-tree - Object identifier of a branch within the MIB tree. Wild

cards can be used to mask a specific portion of the OID string.
(Refer to the examples.)

included - Defines an included view.
excluded - Defines an excluded view.

Default Setting

defaultview (includes access to the entire MIB tree)

Console#show snmp engine-id
Local SNMP engineID: 8000002a8000000000e8666672
Local SNMP engineBoots: 1

Remote SNMP engineID IP address
80000000030004e2b316c54321 192.168.1.19
Console#

Table 4-38 show snmp engine-id - display description

Field

Description

Local SNMP
engineID

String identifying the local engine ID.

Local SNMP
engineBoots

The number of times that the engine has (re-)initialized since
the snmp EngineID was last configured.

Remote SNMP
engineID

String identifying an engine ID on a remote device.

IP address

IP address of the device containing the corresponding
remote SNMP engine.

Advertising