Shutdown, Shutdown -149, Shutdown (4-149) – SMC Networks SMC Tiger 10/100 SMC6128L2 User Manual

Page 449

Advertising
background image

I

NTERFACE

C

OMMANDS

4-149

• To force flow control on or off (with the flowcontrol or no

flowcontrol command), use the no negotiation command to disable
auto-negotiation on the selected interface.

• When using the negotiation command to enable auto-negotiation,

the optimal settings will be determined by the capabilities command.
To enable flow control under auto-negotiation, “flowcontrol” must
be included in the capabilities list for any port

• Avoid using flow control on a port connected to a hub unless it is

actually required to solve a problem. Otherwise back pressure
jamming signals may degrade overall performance for the segment
attached to the hub.

Example
The following example enables flow control on port 5.

Related Commands

negotiation (4 -146)
capabilities (flowcontrol, symmetric) (4-147)

shutdown

This command disables an interface. To restart a disabled interface, use the
no form.

Syntax

[no] shutdown

Default Setting

All interfaces are enabled.

Command Mode

Interface Configuration (Ethernet, Port Channel)

Console(config)#interface ethernet 1/5
Console(config-if)#flowcontrol
Console(config-if)#no negotiation
Console(config-if)#

Advertising