Envelope flanger – KORG TouchView Trinity ProX User Manual

Page 38

Advertising
background image

17: Envelope Flanger

34

17: Envelope Flanger

This Flanger uses an envelope generator for modulation. You will obtain the same pattern of flanging
each time you play. You can also control the Flanger directly using the modulation source.

a

Delay Bottom [msec]

0.0…50.0msec

Sets the lower limit of Delay Time.

P.24

b

Delay Top [msec]

0.0…50.0msec

Sets the higher limit of Delay Time.

P.24

c

Sweep Mode

EG, D-mod

Determines whether the flanger is controled by the enve-
lope generator or by the modulation source.

P.34

Src

None…Tempo

Modulation source that triggers the EG (when EG is
selected for Sweep Mode), or modulation source that
causes the flanger to sweep (when D-mod is selected for
Sweep Mode).

d

EG Decay

1…100

Sets the EG decay speed.

P.34

e

Feedback

–100…+100

Feedback amount

P.32

f

High Damp [%]

0…100%

Feedback damping amount in the high range

P.32

g

Wet/Dry

–Wet…–1:99, Dry,
1:99…Wet

Sets the balance between the effect and dry sounds.

P.25, 32

Src

None…Tempo

Modulation source of effect balance

Amt

–100…+100

Modulation amount of effect balance

c: Sweep Mode
c: Src

This parameter switches the flanger control mode. With Sweep Mode = EG, the
flanger will sweep using the envelope generator. This envelope generator is
included in the envelope flanger, and not related to the Oscillator EG, Filter EG,
or Amp EG.

The Src parameter selects the source that starts the envelope generator. If you
select, for example, Gate, the envelope generator will start when the note-on
message is received.

When Sweep Mode = D-mod, the modulation source can control the flanger
directly. Select the modulation source using the Src parameter.

d: EG Decay

Decay speed is the only adjustable parameter on this EG.

The effect is off when a value for the modulation source specified for the
Src parameter is smaller than 64, and the effect is on when the value is 64
or higher. The Envelope Generator is triggered when the value changes
from 63 or smaller to 64 or higher.

In

Feedback

Wet / Dry

Mono In - Mono Out

High Damp

EG Decay

EG

D-mod

Sweep Mode

D

-mod

Flanger

Advertising
This manual is related to the following products: