03: Multiband Limiter

50

03: Multiband Limiter

This effect applies the Limiter to the low range, mid range, and high range of the input signal. You can
control dynamics for each range to adjust the sound pressure of the low range, mid range, and high range
in a different way from the EQ.

a

Ratio

1.0:1…50.0:1, Inf:1

Sets the signal compression ratio.

P.15

b

Threshold [dB]

–40…0dB

Sets the level above which the compression is applied.

P.15

c

Attack

1…100

Sets the attack time.

P.16

d

Release

1…100

Sets the release time.

P.16

e

Low Offset [dB]

–40…0dB

Gain of the low-range trigger signal

P.50

f

Mid Offset [dB]

–40…0dB

Gain of the mid-range trigger signal

P.50

g

High Offset [dB]

–40…0dB

Gain of the high-range trigger signal

P.50

h

Gain Adjust [dB]

–16…+24dB

Sets the output gain.

P.15

i

Wet/Dry

Dry, 1:99…99:1, Wet

Sets the balance between the effect and dry sounds.

Src

None…Tempo

Modulation source of effect balance

Amt

–100…+100

Modulation amount of effect balance

e: Low Offset [dB]
f: Mid Offset [dB]
g: High Offset [dB]

These parameters set the input gain of the trigger signal.

For example, if you do not want to apply compression to the high range, reduce
the High Offset value down below the Threshold level. In this way, the high
range limiter will not respond, and compression will not be applied.

Left

Right

Wet / Dry

Wet / Dry

Wet: Mono In - Mono Out / Dry: Stereo In - Stereo Out

Gain Adjust

Mid Offset

Low Offset

High Offset

Limiter

Envelope - Control

Envelope - Control

Envelope - Control

Limiter

Limiter

Low

Mid

High

Band-Pass Filters

+