Change Access

2-10

keydata

Enter the WEP key. The key format should be entered as “xx-xx-xx-xx...”
where each x is a hexadecimal digit (0 through 9 and A through F). Each pair
of hex digits (xx) defines a byte of key data, and each byte is separated from
the next by a dash. For a 40-bit key, 5 bytes of key data must be given. For a
128-bit key, 13 bytes of data must be given.

Receive

Determines whether the MSS will receive unencrypted data while WEP is
enabled.

All

Allows reception of encrypted traffic while WEP is enabled. The MSS will
accept unencrypted wireless network frames, as well as frames encrypted with
its WEP key. This is the default setting once WEP has been enabled.

Encrypted

Refuses to accept unencrypted data while WEP is enabled. The MSS will
discard and ignore unencrypted wireless network frames, accepting only
frames encrypted with its WEP key.

Defaults

Disabled, Receive all

Examples

Local>> CHANGE 80211 WEP ENABLED

Local>> CHANGE 80211 WEP INDEX 3

Local>> CHANGE 80211 WEP RECEIVE ENCRYPTED

Local>> CHANGE 80211 RESET

See Also

Show 80211, page 2-63

2.3 Change Access

Specifies which types of connections the specified serial port will accept.

Restrictions

Requires privileged user status.

The None parameter is only valid for the MSS4.

Autobaud must be disabled for ports set to Dynamic and Remote access.

Errors

If a port is active, its access can not be changed.

Parameters

Port

MSS4 only. Specifies a particular port or group of ports.

Note:

In the absence of the Portlist parameter, the configuration will affect the MSS4’s
current port only.

CHANGE PORT PortList ACCESS

LOCAL

DYNAMIC

REMOTE

NONE