Command Reference

Change Autostart

2-13

PortList

Specify a particular port or group of ports. Port numbers are specified with
integers between 1 and 4, and should be separated with commas (for lists) or
dashes (for ranges).

Character

Sets a character that will cause a login event. Users will get the benefit of
Autostart without having to hit Return or enable Autostart for extended periods
of time.

x

Enter the desired alphanumeric character. To specify a control character, use
escaped hex (\xx). For example, Ctrl-B (ASCII character 0x02) would be
specified as \02.

y

Enter the optional second alphanumeric character. To specify a control
character, use escaped hex (\xx). For example, Ctrl-B (ASCII character 0x02)
would be specified as \02.

Any

Sets a wildcard character.

None

Clears the autostart character.

Save

Specifies what happens to the characters that start the connection. Either the
first and/or second autostart characters will be passed to the host as the first
bytes of data, or the characters will be discarded.

None

Discards the autostart characters.

Defaults

Disabled

Examples

Local> CHANGE AUTOSTART ENABLED

Local> CHANGE AUTOSTART CHARACTER A

Local> CHANGE AUTOSTART SAVE 1

See Also

Change Access, page 2-10; Change Autobaud, page 2-11; Change Datasend,
page 2-17; Change Modem Control, page 2-31; Change Modem Emulation,
page 2-32