B: Show 802.11 Errors

B.1 Introduction

When you enter the Show 80211 command without any other parameters, the resulting screen includes a
field for errors. The “Errors:” field displays two eight-digit numbers, separated by a comma. These
numbers are a 64-bit wide bitfield of error bits, each one indicating whether or not the given error has
occurred at least once.

For example, suppose you're using an MSS-Via with a ZoomAir card in Infrastructure mode. After
having been running for a long time, your Access Point loses power in the middle of sending a fragmented
packet to the MSS. If you entered the Show 80211 command, you might see a screen resembling the
following:

Figure B-1: Example of Error Bits

The Errors bitfield is zeroed each time you issue either a Zero command or a Set 802.11 Reset command
at the Local> prompt.

The Errors bitfield is zeroed each time you issue either a Zero command or a Change 802.11 Reset
command at the Local> prompt.

B.2 Error Bits

B.2.1 Leftmost Number

80000000

An authentication or association sequence timed out. An expected reply from
the AP was not received within the required time window.

40000000

Internal error.

20000000

Internal error.

Local_5>> SHOW 80211

802.11 Support: Active

Network Type: Infrastructure

Use MAC address from: MSS (00-80-a3-30-ee-31)

ESS ID: (none set)

Regulatory Region: FCC/USA

DS Channel: Any

RTS Threshold: 3000

Fragmentation Threshold: 2346

Card Present: Zoom Air 4000

Status: Scanning

Errors: 08020002,00000920

Card Firmware Revision: 2.01