Command Reference

Change Startup

2-46

rate

Available speeds (baud rates) are generally 300, 600, 1200, 2400, 4800, 9600,
19200, 38400, 57600, 115200, and 230400 baud. The MSSLite can only go as
high as 38400 baud.

Defaults

9600 baud

See Also

Change Autobaud, page 2-11.

2.59 Change Startup

Configures the startup configuration file that the MSS will attempt to download at boot time. The included
commands will configure the MSS before any users and services are started. If a text hostname is used for
TFTP, the name must be resolvable at boot time, otherwise you must use an IP address.

The Telnet console is available at the time the MSS attempts to download the startup file. If there is a
problem with the download, you can still log into the MSS and determine what went wrong.

Restrictions

Requires privileged user status.

The MSSLite, MSS4, and the MSS-VIA do not support LAT or SPX.

Parameters

Server

MSS4 only.

host:filename

Used to load from a TCP/IP host via TFTP. Enter a TCP/IP hostname or IP
address followed by a colon and a startup file name of up to 47 characters. If
you use a text host name, it must be resolvable at boot time.

node::filename

Used to load from a VAX machine via LAT. Enter the nodename followed by
two colons and the startup file name of up to 47 characters.

node\SYS:\LOGIN\filename

Used to load from a Novell fileserver. Enter the proper node and filename. The
entire path should be no more than 47 characters long.

None

Clears any previously configured startup settings.

Retry

Re-attempts load of the startupfile a certain number of times before giving up.

CHANGE SERVER STARTUP

FILE

host: filename

node:: filename

node\sys:\login\ filename

NONE

RETRY

num