Connecting the Sun Fire V210 server to the MRV LX terminal server

The MCS 5100 platform uses the Sun Fire V210 server medium
configuration.

Note: This server is only available in an AC power configuration.

Procedure 3 Connecting the serial port on the V210 to the MRV LX
terminal server

At the back of the Sun Fire V210 server,

1

Connect the Sun Fire V210 server Net MGT (LOM) serial port
and Serial MGT port to the MRV LX terminal server:

Figure 7 Sun Fire V210 server network callouts

Note 1: The cables with part numbers A0500465 or
NTVW01IM are serial cables.

Note 2: The P1 end goes to the V210 server and the P2 end
goes to the MRV LX terminal server.

ATTENTION

If the network is down, or the server needs to be configured or
restarted, use the console Net MGT port.

By default from manufacturing, the Net MGT serial port is the only
active serial port.