Nortel Networks Sun Fire V210 (RoHS) User Manual

Page 42

Advertising
background image

NN42020-310 MCS 5100 3.5 Standard 1.0 June 2006

42

Copyright © Nortel Networks Limited 2006

7

Enter your password: system [Enter]

8

Define server ip address <IP address of the terminal server>
[Enter]

9

Define server ip subnet mask <ip-address of the subnet
mask>
[Enter]

10

Define server ip primary gateway address <ip address of the
primary gateway>
[Enter]

11

Define port:<select port from range 1-18> telnet newline
filtering cr
[Enter]

Note: Type a range [1-18] for every port the Sun Fire V210
server is connected to.

12

Define port for use with SMDI: Define port 19 telnet newline
filtering none

Note: You can verify the ports with the command:show
ports 1-19 telnet chara [Enter]

13

Save your changes.

14

Log out.

Note: Using the command define saves the configuration.

15

To kill a session on a port, type: logout port 12 [Enter]

Procedure 9 Connecting a server to the MRV LX terminal server

At the management pc,

1

Connect a cat-5 Ethernet cable from the management PC to the
layer-2 switch.

2

Launch PuTTY.

Note: Refer to the customer-specific information datasheet to
enter the MRV LX terminal server IP address and the port
number.

3

In the hostname field, enter <IP address of the MRV LX
terminal server>

ATTENTION

The procedures in this document assume that you are using
PuTTY. It is suggested that you download from the web, PuTTY
VT 100 Emulator, a freeware configurator tool to set up sessions.

Download PuTTY from

www.chiark.greenend.org.uk/~sgtatham/putty/