NCR S10XL User Manual

Page 116

Advertising
background image

Error Messages
System Error Messages

B-4

NCR S10XL Hot Plug Server User Guide

Message

Action

Equipment configuration error

Modify DRAM configuration to agree with one of the
options in the memory configuration shown in Figure
4-4.

Fixed disk controller error

Run Setup.

Fixed disk 0 error

Check all cable connections. Replace fixed disk.

Fixed disk 1 error

Check all cable connections. Replace fixed disk.

Keyboard error or no keyboard
connected

Check and connect the keyboard to the system unit.

Keyboard interface error

Replace the keyboard or contact your dealer.

Memory error at:

MMMM:SSSS:OOO
(W:XXXX,R:YYYY)

where M is MB, S is Segment, O is
Offset, X/Y is write/read pattern

Check the memory size based on the system
specifications. Check the internal cable connections. If
you are sure that connections and values are correct,
ignore the message. If the message reappears, ask for
technical assistance.

Onboard serial port 1 conflict

Run Setup and disable the port.

Onboard serial port 2 conflict

Run Setup and disable the port.

Onboard parallel port conflict

Run Setup and disable the port.

Pointing device error

Check and connect pointing device.

Pointing device interface error

Replace the pointing device or contact your dealer.

Press F1 key to continue or
Ctrl-Alt-Esc for setup

Press [F1] or [Control] + [Alt] + [Esc].