Sample Configurations
Sample RAID Configuration

C-18

NCR S10XL Hot Plug Server User Guide

Adaptec AIC-7870 BIOS v1.2

<<Press hot key for SCSI Select (TM)

Utility>>

(Refer to the Adaptec SCSI Manual for additional
information about these settings).

2.

Select SCSI Disk Utilities. Observe that the
information that displays for the 2 GB disk drive
and the CD-ROM drive is correct. If a low-level
format on the 2 GB disk drive is needed, perform it
now. It is usually not needed.

3.

Select Configure/View Host Adapter Settings and
set the parameters as follows:

SCSI Bus Interface Definitions
Host Adapter SCSI ID

[7]

SCSI Parity Checking

[Enabled]

Host Adapter SCSI Term

[Low ON/High ON]

Boot Device Options:
Boot Target ID

[0]

Boot LUN Number

[0]

4.

Select SCSI Device Configuration and set the
parameters as follows:

SCSI Device ID (tab to desired device)
Initiate Sync Negotiation

[yes]

Maximum Sync Transfer Rate

[20]

Enable Disconnection

[yes]

Initiate Wide Negotiation

[yes]

Send Start Unit Command

[yes]