Sample raid configuration, Installing the hardware, C-12 – NCR S10XL User Manual

Page 132

Advertising
background image

Sample Configurations
Sample RAID Configuration

C-12

NCR S10XL Hot Plug Server User Guide

Sample RAID Configuration

A RAID configuration might consist of the following:

Pentium 166 MHz Processor w/ECC Mem Support

128 MB System Memory

ISA Video Board with 1 MB Video RAM

PCI Ethernet Adapter (SMC8432BTA)

PCI Token Ring Adapter (Olicom OC-3136)

PCI RAID Adapter (Mylex)

Four 4 GB SCSI wide hard drives connected to the
Mylex RAID controller

One 2 GB SCSI wide hard drive connected to the
onboard AIC-7870 SCSI controller

SCSI CD-ROM drive connected to the onboard
AIC-7870 SCSI controller

To install the hardware, follow these steps:

1.

Split the hot plug backplane.

2.

Strap the 2 GB wide drive as SCSI ID 0. Plug it into
the hot plug backplane in drive bay 1 (top).

3.

Strap the CD-ROM drive as SCSI ID 3. Insert it into
the top, front 5.25-inch drive bay. Connect the power
cable and the narrow SCSI cable to the CD-ROM
drive.

Installing the
Hardware