Replacing media bay modules, Figure 56, Process map: replacing a media bay module – Nortel Networks BCM1000 User Manual

Page 156

Advertising
background image

156

Chapter 8 Installing media bay modules

P0607659 02

Replacing media bay modules

When media bay modules require replacement, follow the steps in this section.

Figure 56

Process map: Replacing a media bay module

If a media bay module fails, follow this procedure to properly replace the module.

1

Follow the steps in

“Shutting down the system” on page 152

to ensure the system shuts down

correctly.

2

Remove the front bezel from the unit where the module resides.

3

Pull the latch beside the module to be replaced to release the module. Refer to

Figure 54 on

page 153

.

4

Slide the module out of the bay where it is installed.

5

Record the switch settings from the old module.

Warning:

This section describes replacing a module with the same type of module. If you

want to replace a module with a different type of module, you must treat it as a new
installation. Refer to

Chapter 7, “Setting media bay module DIP switches,” on page 135

and review

Figure 51 on page 140

to ensure the new module does not overrun any lines

already assigned to other modules.

Module

failure

Disconnect cables

from the front of
the BCM1000 and
BCM1000e

Remove power

from both units

Remove front bezel

from BCM1000 or
BCM1000e

Remove failed
module

Set DIP switches

on new module to
match old module

Install new module

in media bay

Replace
coverplate

Restore power

to

BCM1000 and
BCM1000e

Reconnect all
cables

Monitor LEDs

for

power and status

Check the module
settings in the Unified
Manager

Advertising