Chapter 15 Troubleshooting

P0607659 02

3

To set the parameters for the System Status Sanity check, click the LED Settings tab.

The LED Settings record appears.

Figure 98

System Status Monitor LED Settings record

Table 43

lists the values on the LED Settings screen.

Emergency telephone does not function

If the emergency telephone is connected to the system, use the following procedure:

1

Check the power LED on the ASM 8 to check that the ASM 8 is receiving power.

2

Check that the emergency telephone has dial tone.

3

Check the external line and emergency telephone connections.

4

To avoid damage to the emergency telephone, connect the telephone directly to the external
line and check for dial tone.

5

Replace the MSC.

Table 43

LED Display screen settings

Attribute

Values

Description

Version

Read only.

The current version of the LED monitoring application.

Reset

Yes, No, N/A

Use Yes to allow the system status monitor board to reset the
computing platform in the event that the sanity check fails the
user set parameters.

Sanity Time

60-255

Default: 240

The time in seconds between sanity checks.

Timeouts

0-254

Default: 10

The number of sanity checks that must fail before the system
status monitor sends a reset signal to the computing platform.