Nortel Networks BCM1000 User Manual

Page 36

Advertising
background image

36 BCM1000, BCM 3.0 addendum

Installation and Maintenance Guide

P0607659 02

DSM16/DSM 32 single density switch settings (upgraded system)

The following table shows the switch settings for DSM modules deployed as single density on a system that has
been upgraded from Business Communications Manager version 2.5 to version 3.0. All your current modules are
probably single-density modules. If you intend to continue to use them, you do not have to change any settings.
They will continue to function in the same manner as before.

DSM16+ and DSM32+ modules can be set to either density. To set them for single density, refer to the following
table. To set them to double density, refer to the table under

DSM16+ and DSM 32+ double density switch

settings (upgraded system)

on page 37.

Note that Companion sets can only be assigned on DS30 06 and 07, which have single-density DSM modules.
Companion handsets have a different set of default DNs than the digital sets. Also, Companion can only be
deployed on systems that remain at Part Double Density (PDD), the default condition of 3.0 systems.

Table 1 ASM8 settings for 2.5 systems upgraded to 3.0 software

Select

bus

Select

offset

Enter these switch

settings

To assign

these

DNs

1

Select

bus

Select

offset

Enter these switch

settings

To

assign

these

DNs

1

Custom DN

range

1

2

3

4

5

6

1

2

3

4

5

6

2.5 system upgraded to 3.0

2.5 system upgraded to 3.0

02

0

on on on on on on 221-228

05

0

on on on on

off on 269-276

1

on on off on on on 228-236

1

on on off on

off on 277-284

2

on off on on on on 377-384

2

on off on on

off on 425-432

3

on off off on on on 385-392

3

on off off on

off on 433-440

03

0

on on on on on off 237-244

06

0

on on on on

off off 285-292

1

on on off on on off 245-252

1

on on off on

off off 293-300

2

on off on on on off 393-400

3

2

on off on on

off off 441-448

3

on off off on on off 401-408

3

3

on off off on

off off 449-456

04

0

on on on on off on 253-260

07

2

0

on on on off

on on 381-388

1

on on off on off on 261-268

1

on on off off

on on 389-396

2

on off on on off on 409-416

4

2

on off on off

on on 457-464

3

on off off on off on 417-424

4

3

on off off off

on on 465-472

1

The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different

Start DN, enter the range in the blank column.

2

If your system is configured with a 3/5 channel split, DS30 07 is not available.

3

Available only on systems set to FDD.

4

Available only on systems set to FDD, with a 2/6 DS30 split.

Table 2 DSM 16/DSM 16+ and DSM 32/DSM32+ single density switch settings for 2.5 systems upgraded to 3.0

Select

DS30

bus

Enter these switch

settings

1

To assign

these DNs

to

DSM16 or

DSM 16+

To assign these DNs to

DSM 32 or

DSM 32+

4

To assign these DNs

to Companion

1

2

3

4

5

6

02

on

on

on

on on on

221-236

221-252 (DS30 02 and 03)

N/A

03

on

on

on

on on off

237-252

237-268 (DS30 03 and 04)

04

on

on

on

on off on

253-268

253-284) (DS30 04 and 05)

05

on

on

on

on off off

269-284

269-300 (DS30 05 and 06)

06

on

on

on

off on on

285-300

285-316 (DS30 06 and 07)

3

565-580

(PDD only

)

2

07

on

on

on

off on off

301-316

N/A

3

581-596

(PDD only

)

Advertising