Installing a data communication device, Figure 90, Data communication device installation overview – Nortel Networks BCM1000 User Manual

Page 225

Advertising
background image

Chapter 13 Installing Analog Terminal Adapters

225

Installation and Maintenance Guide

Installing a data communication device

Figure 90

shows the hardware configuration for connecting a data communication device through

an ATA 2 to the Business Communications Manager.

Figure 90

Data communication device installation overview

The following steps explain how to install an ATA 2 to a data communication device.

1

Connect a single-line telephone to the ATA 2.

2

Check that the ATA 2 is in the Tones OFF mode, lift the handset and enter LINK 18.

3

Make sure the terminal loop resistance is less than or equal to 200 ohms.

4

Disconnect the single-line telephone from the ATA 2.

5

Plug the data communication device into ATA 2.

Note:

LINK appears as RECALL on some telephones. If you are using a telephone

without a LINK or RECALL button, refer to the Business Communications Manager
ATA2 User Guide
for details.

Note:

If necessary, install the ATA 2 near to the data communication device to maintain a

maximum loop resistance of less than 200 ohms. When using 0.4 mm wire (26 AWG), the
ATA 2 must be within 800 m (2,600 ft.) of the BCM1000.

Data communication
device

Business Communications
Manager ATA2

Business Communications
Manager

Line loop resistance:
135 ohms maximum

Terminal loop resistance:
200 ohms maximum

Central
Office

ATA 2 power cord

Advertising