Chapter 10 Wiring the modules

P0607659 02

Figure 65

shows the wiring pin-out for a BRI to the service provider (BRI loop set to T)

This diagram also applies to an S-Loop BRI, allowing connection to such S-Loop devices as
video phones, terminal adapters, and Grp 3 Fax machines.

Figure 65

BRI RJ45 wiring array

3

Insert the connector into the jack on the module.

4

You can now use the Unified Manager to configure the lines or sets associated with the
module.

Refer to the Business Communications Manager Programming Operations Guide for steps
about changing the default settings for each line/loop.

Warning:

The BRI must only be connected to an NT1 provided by the service provider.

The NT1 must provide a Telecommunication Network Voltage (TNV) to Safety Extra
Low Voltage (SELV) barrier.

8 7 6 5 4 3 2 1

BRI connector

RJ45 sockets

Pin #/connection

System side

1

not used

2

not used

3

+RX

4 +TX

+TX

+RX

5

- TX

6

-RX

- RX

-TX

7

not used

8

not used