Figure 70, Rpi mounting holes, Figure 71 – Nortel Networks BCM1000 User Manual

Page 195: Opening the rpi cover

Advertising
background image

Chapter 12 Installing the Companion system

195

Installation and Maintenance Guide

This procedure explains how to mount the RPI unit.

1

Partially screw in two #10 50 mm (2 in.) screws using the dimensions shown in

Figure 70

.

Figure 70

RPI mounting holes

2

Open the cover with a screwdriver.

a

Use the screwdriver to push in, and then down, to release the latch on the right side.

b

Remove the cover by lifting it up. Refer to

Figure 71

.

Figure 71

Opening the RPI cover

3

Hang the RPI on the two screws and tighten the screws.

4

Install the remaining two screws.

325 mm

(13 in.)

25 mm

(1 in.)

50 mm

(2 in.)

300 mm

(12 in.)

Keyholes