Chapter 12 Installing the Companion system

P0607659 02

RPI output connections

Feed the output pairs in through the bottom of the RPI and route the pairs to the output connectors.

Figure 74

shows how to route the output pairs. If you use one pair to power a base station, connect

the power pair to -PWR(1) and +PWR(1). If you use two pairs to power a base station, connect one
pair to -PWR(1) and +PWR(1), and the second pair to -PWR(2) and +PWR(2).

Figure 74

Output connector pinout

RPI input connections

Feed the TCM input pairs from the Business Communications Manager distribution frame through
the top of the RPI and route them to the input connectors (IBIX1 to IBIX4).

Figure 75

shows how to route the input pairs. The maximum number of input pairs in an RPI

installation is 16.

Table 37

lists the pinout and signal references.

Figure 75

Input connector pinout

Caution:

Ensure both pairs have the same polarity.

If you connect two power pairs with opposite polarities, you can damage the base
station and RPI.

OBIXn

-PWR(1)

TCM

TCM

+PWR(1)

-PWR(2)

+PWR(2)

OBIXn

-PWR(1)

-PWR(2)
TCM
TCM

+PWR(1)

+PWR(2)

IBIXn