Chapter 13 Installing Analog Terminal Adapters

221

Installation and Maintenance Guide

Follow these steps to connect the cable.

1

Connect one end of a line cord to the ATA2 Terminal jack. Refer to

Figure 88

.

Figure 88

ATA 2 top view

2

Connect the other end to your telephone, modem or FAX.

3

Connect one end of a line cord to the ATA2 Line jack.

4

Connect the other end to an available station port on the BCM1000 or BCM1000e.

5

For a 120 V or 230 V system, plug the DIN connector of the power supply cord into the power
supply connector receptacle. Plug the adapter into a standard ac outlet.

Mounting the ATA 2

After the ATA 2 is correctly connected, you can mount the unit on a wall, as described in this
section.

1

When using 0.5 mm wire (24 AWG), select a location within 800 m (2,600 ft.) of the
BCM1000.

2

Allow 12.5 cm (5 in.) clearance for the line jack, terminal jack, and power supply connector.

3

Screw two 4 mm (#8) screws into the wall, 130 mm (5 1/4 in.) away from each other. Leave
6 mm (1/4 in.) of the two screws showing.

4

Align the slots at the back of the ATA 2 unit over the screws. Push the unit against the wall.
The line jack, terminal jack and power supply connector must be at the top of the ATA 2. Refer
to

Figure 89

.

Caution:

In North America, the ATA 2 must be powered from a Class 2 power source

that is UL and CSA approved.
In Europe, the ATA 2 must be powered from a Class II power source that is CE marked.

=

24 V

~

0.006 A

Telephone jack

Line jack

Power supply connector receptacle