DSM16+ and DSM 32+ double density switch settings (upgraded system)

The following table shows the switch settings for DSM-plus modules deployed as double density on a system that
has been upgraded from 2.5 to 3.0.

1

The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different

Start DN, enter the range in the blank column.

2

If your system is configured with a 3/5 DS30 split, you cannot use DS30 07 for the DSM 16 module. You cannot

configure the DSM32 module for DS30 06 because the second set of DNs cannot be accessed.

3

If you need more DNs for Companion sets, use the range that starts at 597 (ISDN or DECT) and change the

DN type to NA Portable.

4

If you system is set to Full Double Density (FDD), Companion telephones are not supported.

Note: DSM modules deployed with 2.5 systems are all single density and cannot be set to double density.
The DSM 16+ and DSM32+ modules can be set to either density.

Table 3 DSM 16+ and DSM32+ double density switch settings for 2.5 systems upgraded to 3.0

Select

DS30

bus

Enter these switch settings

**To assign these DNs to

DSM

16+:

(A= DSM1, B=DSM2)

To assign these DNs to

DSM 32+

(connectors: A=top,

B = bottom)

1

2

3

4

5

6

02

off

on

on

on

on

on

A

221-236

A

377-392

off

on

off

on

on

on

B

377-392

B

221-236

03

off

on

on

on

on

off

A

237-252

A

393-408

off

on

off

on

on

off

B

393-408

B

237-252

04

off

on

on

on

off

on

A

253-268

A

409-424

off

on

off

on

off

on

B

409-424

B

253-268

05

off

on

on

on

off

off

A

269-284

A

425-440

off

on

off

on

off

off

B

425-440

B

269-284

06

off

on

on

off

on

on

A

285-300

A

441-456****

off

on

off

off

on

on

B

441-456****

B

285-300

***07

off

on

on

off

on

off

A

301-316

A

457-472*****

off

on

off

off

on

off

B

457-472*****

B

301-316*****

**The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different
Start DN, enter the range in the blank column.
***If your system is configured with a 3/5 split, you cannot use DS30 07 for the DSM 16 module.
****Available only on systems set to FDD. Modules cannot be set to double density on systems set to PDD. Refer to the
previous chart for the switch settings for single density and PDD.
*****Available only on systems set to FDD, with a 2/6 DS30 split. Modules cannot be set to double density on systems set
to PDD. Refer to the previous chart for the switch settings for single density and PDD.

Table 2 DSM 16/DSM 16+ and DSM 32/DSM32+ single density switch settings for 2.5 systems upgraded to 3.0