Replacing a redundant power supply module, Figure 137 removing the power module – Nortel Networks BCM1000 User Manual

Page 277

Advertising
background image

Chapter 19 Replacing a power supply

277

Installation and Maintenance Guide

Replacing a redundant power supply module

If the green LED for the power supply is not lit, but the power switch on the module is on, it
indicates that the module has failed.

Follow these steps to replace the redundant power supply module.

1

Turn the module switch to OFF.

2

Remove the screw from right-hand tab.

3

Grasp the handle on the module and, at the same time, pull the locking tab on the left of the
module towards the handle of the module.

4

Pull the module straight forward and out of the housing. Refer to

Figure 137

.

Figure 137

Removing the power module

5

Ensure the switch on the replacement module is off.

6

Insert the replace module into the empty slot in the power supply housing.

You will hear a click when it is seated properly.

7

Secure with a screw in the tab located on the right side of the module.

8

Turn the module switch to the on position.

The LEDs on the power supply are on when the ac power is connected.

Note:

It is not necessary to remove power from the BCM1000 or BCM1000e to replace a

redundant power supply module.

Locking tab

Module screw