Figure 67, Wiring for an asm 8, Table 32 – Nortel Networks BCM1000 User Manual

Page 181: Asm wiring chart, Connect amphenol cable

Advertising
background image

Chapter 10 Wiring the modules

181

Installation and Maintenance Guide

Table 32

and

Figure 67

provide the wiring scheme for the eight pairs that connect to the ASM.

3

Plug the female amphenol connector into the interface on the front of the module.

41

Yellow-Blue

X16

16

32

16

Blue-Yellow

X16

16

32

42-40

17-25

no connections

Table 32

ASM wiring chart

Pin

Wire color

Port

Set

Figure 67

Wiring for an ASM 8

26

White-Blue

X01

1

1

Blue-White

X01

1

27

White-Orange

X02

2

2

Orange-White

X02

2

28

White-Green

X03

3

3

Green-White

X03

3

29

White-Brown

X04

4

4

Brown-White

X04

4

30

White-Slate

X05

5

5

Slate-White

X05

5

31

Red-Blue

X06

6

6

Blue-Red

X06

6

32

Red-Orange

X07

7

7

Orange-Red

X07

7

33

Red-Green

X08

8

8

Green-Red

X08

8

34-50

no connection

9-25

Note:

Refer to

“Line and extension numbers for specific modules” on page 141

to see the

relationship between the DS30 channel number and the DNs. Configuration information is
included in the chapters on setting up modules and DNs in the Business Communications
Manager Programming Operations Guide
.

Table 31

DSM wiring chart (Continued)

Pin

Wire color

Port

Sets
1st

Sets
2nd

8R

33T

32T

7R

31T

6R

30T

5R

29T

4R

28T

3R

27T

2R

26T

1R

25-pair female
amphenol
connector

Advertising