Mode 1 output timing, Figure 4-39. mode 1 output timing, Mode 1 output timing -53 – National Instruments AT E Series User Manual

Page 100

Advertising
background image

Chapter 4

Connecting Signals

© National Instruments Corporation

4-53

AT E Series User Manual

Mode 1 Output Timing

Figure 4-39 details the timing specifications for an output transfer in
Mode 1.

Figure 4-39. Mode 1 Output Timing

Name

Description

Minimum

Maximum

T1

WR* = 0 to INTR = 0

250

T2

WR* = 1 to Output

200

T3

WR* = 1 to OBF* = 0

150

T4

ACK* = 0 to OBF* = 1

150

T5

ACK* Pulse Width

100

T6

ACK* = 1 to INTR = 1

150

All timing values are in nanoseconds.

WR*

OBF*

INTR

ACK*

DATA

T1

T2

T3

T4

T5

T6

Advertising