Timing i/o – National Instruments AT E Series User Manual

Page 140

Advertising
background image

Appendix A

Specifications for AT-MIO-16XE-50

© National Instruments Corporation

A-35

AT E Series User Manual

Digital logic levels

Power-on state........................................ Input (high-impedance)

Data transfers ......................................... Programmed I/O

Max transfer rate (1 word = 8 bits) ........ 50 kwords/s, system dependent

Constant sustainable rate........................ 1 to 10 kwords/s, typical

Timing I/O

Number of channels ............................... 2 up/down counter/timers,

1 frequency scaler

Resolution

Counter/timers ................................ 24 bits

Frequency scaler ............................. 4 bits

Compatibility ......................................... TTL/CMOS

Base clocks available

Counter/timers ................................ 20 MHz, 100 kHz

Frequency scaler ............................. 10 MHz, 100 kHz

Base clock accuracy ............................... ±0.01%

Max source frequency ............................ 20 MHz

Min source pulse duration...................... 10 ns, edge-detect mode

Min gate pulse duration.......................... 10 ns, edge-detect mode

Level

Min

Max

Input low voltage

0 V

0.8 V

Input high voltage

2 V

5 V

Input low current (V

in

= 0 V)

–320 µA

Input high current (V

in

= 5 V)

10 µA

Output low voltage (I

OL

= 24 mA)

0.4 V

Output high voltage (I

OH

= 13 mA)

4.35 V