National Instruments AT E Series User Manual

Page 53

Advertising
background image

Chapter 4

Connecting Signals

AT E Series User Manual

4-6

ni.com

PA<0..7>

DGND

Input or

Output

Port A—These pins are port A of the extra digital I/O signals
on the AT-MIO-16DE-10.

PB<0..7>

DGND

Input or

Output

Port B—These pins are port B of the extra digital I/O signals
on the AT-MIO-16DE-10.

PC<0..7>

DGND

Input or

Output

Port C—These pins are port C of the extra digital I/O signals
on the AT-MIO-16DE-10.

+5V

DGND

Output

+5 VDC Source—These pins are fused for up to 1 A of
+5 V supply. The fuse is self-resetting.

SCANCLK

DGND

Output

Scan Clock—This pin pulses once for each A/D conversion
in the scanning modes when enabled. The low-to-high edge
indicates when the input signal can be removed from the
input or switched to another signal.

EXTSTROBE*

DGND

Output

External Strobe—This output can be toggled under software
control to latch signals or trigger events on external devices.

PFI0/TRIG1

DGND

Input

Output

PFI0/Trigger 1—As an input, this is either one of the
Programmable Function Inputs (PFIs) or the source for
the hardware analog trigger. PFI signals are explained in
the

Timing Connections

section later in this chapter.

The hardware analog trigger is explained in the

Analog

Trigger

section of Chapter 3,

Hardware Overview

.

Analog trigger is available only on the AT-MIO-16E-1,
AT-MIO-16E-2, AT-MIO-16XE-10, AT-AI-16XE-10, and
the AT-MIO-64E-3.

As an output, this is the TRIG1 signal. In posttrigger data
acquisition sequences, a low-to-high transition indicates
the initiation of the acquisition sequence. In pretrigger
applications, a low-to-high transition indicates the initiation
of the pretrigger conversions.

PFI1/TRIG2

DGND

Input

Output

PFI1/Trigger 2—As an input, this is one of the PFIs.

As an output, this is the TRIG2 signal. In pretrigger
applications, a low-to-high transition indicates the initiation
of the posttrigger conversions. TRIG2 is not used in
posttrigger applications.

PFI2/CONVERT*

DGND

Input

Output

PFI2/Convert—As an input, this is one of the PFIs.

As an output, this is the CONVERT* signal. A high-to-low
edge on CONVERT* indicates that an A/D conversion is
occurring.

Table 4-2. I/O Signal Summary for the AT E Series (Continued)

Signal Name

Reference

Direction

Description

Advertising