VXI 3002 User Manual

Page 120

Advertising
background image

5-45

Table 5-29 Internal

Φ

M flatness test

Modulation

frequency (kHz)

Response

level min.

(dB)

Result (dB)

Response
level max.

(dB)

0.1

−3

_______ +3

0.3

−3

_______ +3

1

reference

3

−3

_______ +3

10

−3

_______ +3

Table 5-30 Internal AM depth and distortion tests at

4 dBm

AM depth 30%

AM depth 80%

Distortion

Carrier

frequency

(MHz)

min.

(%)

Result

(%)

max.

(%)

min.

(%)

Result

(%)

max.

(%)

Result at

30% depth

(<1.5%)

Result at

80% depth

(<2.5%)

1.5 28.5

_____

31.5

76

_____

84

_______

_______

6 28.5

_____

31.5

76

_____

84

_______

_______

9 28.5

_____

31.5

76

_____

84

_______

_______

11 28.5

_____

31.5

76

_____

84

_______

_______

20 28.5

_____

31.5

76

_____

84

_______

_______

50 28.5

_____

31.5

76

_____

84

_______

_______

100 28.5

_____

31.5

76

_____

84

_______

_______

200 28.5

_____

31.5

76

_____

84

_______

_______

500 28.5

_____

31.5

76

_____

84

_______

_______

Table 5-31 Internal AM depth and distortion tests at +7 dBm

AM depth 30%

AM depth 80%

Distortion

Carrier

frequency

(MHz)

min.

(%)

Result

(%)

max.

(%)

min.

(%)

Result

(%)

max.

(%)

Result at

30% depth

(<1.5%)

Result at

80% depth

(<2.5%)

1.5 28.5

_____

31.5

76

_____

84

_______

_______

6 28.5

_____

31.5

76

_____

84

_______

_______

9 28.5

_____

31.5

76

_____

84

_______

_______

11 28.5

_____

31.5

76

_____

84

_______

_______

20 28.5

_____

31.5

76

_____

84

_______

_______

50 28.5

_____

31.5

76

_____

84

_______

_______

100 28.5

_____

31.5

76

_____

84

_______

_______

200 28.5

_____

31.5

76

_____

84

_______

_______

500 28.5

_____

31.5

76

_____

84

_______

_______

Advertising