5-14

Phase modulation

Specification

Deviation

0 to 10 radians.

Resolution

3 digits or 0.01 radians.

Accuracy at 1 kHz

±5% of indicated deviation excluding residual phase modulation.

Bandwidth (3 dB)

100 Hz to 10 kHz.

Distortion

Less than 3% at 10 radians at 1 kHz modulation rate. Typically <0.5% for deviations up
to 1 radian at 1 kHz.

Test equipment

Description Minimum

specification Example

Modulation meter

ΦM and FM accuracy ±2% at 1 kHz modulation

frequency

IFR 2305 with
distortion option

Phase modulation

Test procedure

(1) Connect the test equipment as shown in Fig. 5-7.

(2) On the UUT set:

Carr Freq

10.5 MHz

RF Level

0 dBm

Source

On

Mod Mode

PM Internal

PM1 Level

10 rad

(3) On the modulation meter, select CAL,

Φ

M.

(4) Measure

the

Φ

M accuracy and distortion checking that the results are within the specification

shown in Table 5-28.

Phase modulation flatness

Test procedure

For this test, the phase modulation figures are calculated from readings taken with the modulation
meter set to FM. No allowances need to be made for the modulation source frequency accuracy
since it is derived from the reference oscillator in the UUT.

(1) Connect the test equipment as shown in Fig. 5-7.

(2) On the UUT set:

Carr Freq

15 MHz

RF Level

0 dBm

Mod Mode

PM Internal

Source

On

Mod

On

PM1 Level

10 rad

(3) On the modulation meter, select CAL, FM, 50 Hz

Þ

15 kHz LF filter.

(4) Measure the deviation on the modulation meter and calculate the phase modulation using the

formula:

ю

э

ь

о

н

м

=

Φ

(Hz)

freq

mod

(Hz)

dev

FM

M

(5) On the UUT set mod source to each of the frequencies shown in Table 5-29, measure the

deviation on the modulation meter and calculate the phase modulation for each step using the
formula in (4).