K5 System Technical Guide

3) Event up

Event up setting decides which switchboard should the alarm and events be sent to. We can
adopt the default setting, or untick to set the switchboard we want. Maximum 4 switchboards can
be set to one C5-IPC, and the events will be sent to all the switchboards at one time.

4) MDS

MDS serves as multi- door station switcher. When there are more than one door station in one
block, it must be used to make the system work properly. The system now allows maximum 2 C5-
MDS to work at one block. Any one of the 4 ports of C5-MDS can be connected to door station, or
camera or None.

Door Station: The port is connected to Door Station
Camera: The port is connected to camera
None: the port is left empty

Note:

To set different devices for each port of C5-MDS can effect smart detection, when monitor