Chapter 2 k5 system parts, C ~ +40 – V-Tech CAT5 System Technical Guide User Manual

Page 30

Advertising
background image

Page 30

K5 System Technical Guide

JWP: Power input. P+, positive 24V; P-,

negative.

JWB (IN1, IN2, IN3, IN4): Connected to

door stations (Max.4).

PA: Test button. Press PA, the IN-USE

indicator will light, and then start to
monitor door station connected circu-
lar with click of relay.

S1: DIP Switch function setting, refer to

DIP switch setting.

SW1: Always set to the 2V, 2A position.

JTAG: update port. Connected to PC to

update the firmware of C5-MDS

RS-485: PC port. Used to update the firmware of C5-MDS.

Specification

• Power input:

DC 24V

• Standby Current:

50mA

• Working Current:

80mA

• Connection Port:

RJ45

• Working temperature:

-10

0

C ~ +40

0

C

• Dimension:

140*150*60 mm

2.3.4.6§Picture§Memory§Controller:§C5-IMC

C5-ICM is independent picture memory controller for K5 system. When visitor call the monitor, the
C5-IMC will start to capture picture and save it, the resident can view the picture on the indoor
monitor.

• Picture playing is continuous and the switch time can be set by DIP switch

• Up to 800 pictures can be saved

Parts and functions

S201: DIP switch

PA201: Capture picture in normal status, for DIP test in test status

PA202: Play picture in normal status, for EEPROM test in test status

PA203: Exit in normal status, for monitor communication in test status

C5-MDS

JWB(IN4)

P- P+ P- P+

PA

S1

1

ON

DIP

2

3

4

5

6

JWB(IN3) JWB(IN2) JWB(IN1)

JWB(OUT)

JWB(OUT)

T/R-

ERROR

INUSE

LINK

POWER

T/R+

JWP

PA

S1

ERROR

IN-USE

LINK

POWER

RS-485

JWB(IN4) JWB(IN3) JWB(IN2) JWB(IN1)

Chapter 2 K5 System Parts