V-Tech CAT5 System Technical Guide User Manual

Page 29

Advertising
background image

Page 29

K5 System Technical Guide

station only

JWB (OUT): Bus Signal Output. RJ45 port includes audio, data & video. It can be connected to

distributor.

CN-MDS: Bus Signal Input. RJ45 port, connected to MDS only

CN-NET: RJ45 Network Port, connected to LAN

JP1/JP2/JP3: Jumper. Removed if C5-MDS connected

SWI: Distributor Setting. Match different distributor

Specifications

Power input:

DC 24V

Standby Current:

185mA

Working Current:

250mA

Video Signal:

CCIR, 1Vp-p, 75Ω

Audio Signal:

300~3,400 KHz, 0~240 mV

Transmission Mode:

TCP/IP

Connection Port:

RJ45

Network Interface:

Standard Ethernet interface

Working temperature:

-10

0

C ~ +40

0

C

Dimension:

140*150*60 mm

2.3.4.5§Multi-Door§station§Switcher:§C5-MDS

C5-MDS is used when there are more than one door stations in one block. It serves as a door sta-
tion switcher, to separate video and audio signal for each door station

• 4 door stations can be connected to 1 C5-MDS

• Max. 2 pieces of C5-MDS switchers per block

Parts and Functions

POWER: Power indicator. Always ON while working.

LINK: Signal indicator. Flicker means signal is transmitted in bus, always ON means communica-

tion ERROR in bus.

IN-USE: Status Indicator. ON while working.

ERROR: Error indication. ON when equipment failure.

JWB (OUT): Output port. RJ45 port, connected to C5-IPC.

Advertising