4§parameters§settings, 5§controller§concept, Page 75 k5 system technical guide – V-Tech CAT5 System Technical Guide User Manual

Page 75

Advertising
background image

Page 75

K5 System Technical Guide

4.4.2.4§Parameters§Settings

All the parameters of C5-IPC can be set through IP-Device. See IP-Device manual for detail.

4.4.2.5§Controller§Concept

Controller in the system serves as the controlling center, it controls data communicating, audio
and video distribution. Of all the devices, Door station and C5-IPC can be set to be the controller.
Rules must be followed as below:

1) There must be one and only one controller in the system.

2) C5-IPC is designed to be the controller by default, and cannot be set to be non-controller

3) Door station must be set to be non-controller when working with C5-IPC.

How to set Controller on door station:

V i d e o E n t r y S y s t e m

- - - - - - - - - - - - - - - - - - - - - - - - - - -

- - - - - - - - - - - - - - - - - - - - - - - - - - -

> > D E B U G S T A T E < <

- - - - - - - - - - - - - - - - - - - - - - - - - - -

3 - # M o n i t o r P r o g r a m

2 - # S e t u p

1 - # I n s t a l l e r S e t u p

6 - # O n l i n e D e v i c e s . . .

E X I T: # - 9 0 0 9

5 - # O n l i n e M o n i t o r. . .

- - - - - - - - - - - -To o l s - - - - - - - - - -

4 - # C a r d M a n a g e

V i d e o E n t r y S y s t e m

* B a c k

P r e s s 1 ~ 9 t o s e l e c t

- - - - - - - - - - - - - - - - - - - - - - - - - - -

8. I n s t a l l e r C o d e

7. P a r a m e t e r s . . .

6. A u d i o O p t i o n . . .

5. D o o r p l a t e M o d e . . .

4. C a r d M e m o r y

3. U n l o c k O u t p u t

2. U n l o c k T i m i n g

[ 1] I n s t a l l e r S e t u p

1. D S S e r i a l N O .

- - - - - - - - - - - - - - - - - - - - - - - - - - -

9. D e f a u l t. . .

V i d e o E n t r y S y s t e m

. . [ 1 ] [ 1 ]

* B a c k # S a v e

( 0~ 9 )

[ - ]

D S S e r i a l N O .

0: 1D S S t a n d a l o n e
1~ 8 : M u l t i D S N O.

9: C o m m o n D o o r S t a t i o n

In standby mode, in-
put #9008+password
(66666666, by default)

On the keypad, input 1 to
enter DS Serial NO.

Input the number according
to the information, then # to
save the parameter

Notes:
1. DS Serial NO. set to be 0, the door station serves as the controller

2. DS Serial set to be from 1~8 to be non-controller, if there is no C5-MDS(only one

door station), the door station must be set to 1

3. DS Serial NO. set to 9 to work as common door station

Advertising