3§monitor§setting, 1§concept§of§address, Chapter 4 k5 system settings – V-Tech CAT5 System Technical Guide User Manual

Page 60: 2§door§lock§controlled§with§external§power, Page 60 k5 system technical guide, Ip-mr18 ac

Advertising
background image

Page 60

K5 System Technical Guide

LOCK

PS5

1

2

3

6

5

4

7

8

9

#

0

*

RF CARD

CN1

CN2

CN-LK

J/KMB

JP-LK

Bus

EB+ EB-

N.O

LK+

LK-

+12V

1

2

3

T/R- T/R+

IP-MR18

AC

+

-

+ -

To C5-IPC or Distributor

LOCK

Exit Button

Remove the

jumper

POWER

SUPPLY

Note:

1. Please use DC lock and the related DC power supply

2. Remove the JP-LK jumper

3. Set Unlock Output(unlock mode) for diffirent lock types(#8001-3: Unlock Output)

• Power-on-to-unlock type:Unlock Output=0 (by default)

• Power-off-to-unlock type:Unlock Output=1

4.2.2.2§Door§Lock§Controlled§with§External§Power

§

§ 4.3§Monitor§Setting

4.3.1§Concept§of§Address

Address codes are the numbers/letters used by residents, visitors and Switchboard operators to
identify the apartments or villas in the installation. Inside the unit/riser each apartment can be
addressed with a 4 digit code(ABCD),of these 4 digits, the first 2 digits are meant to be the floor
number, while the last 2 digits serves as the monitor code of each floor. There are 2 calling types
when there is cal made to the monitor: Inside call and Outside call.