Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-751-G2 User Manual

Page 44

Advertising
background image

5. Assembly

44

PNEG-751-G2 12" Series II Sweep 131' and 135' Diameter

H. Feed each of the six (6) 14 AWG stranded wires through the 3/4" rigid conduit assembly and cut

them off, leaving six inches (6") at both the left junction box and drive motor.

I. Feed each of the six (6) 10 AWG stranded wires cord through the 3/4" x 40" liquid-tight flex conduit

and cut four (4) of them off, leaving six inches (6") at both the right junction box and auger motor.
Cut the 10 AWG blue and yellow wires longer so they can be connected to the 14 AWG blue and
yellow wires in the left junction box.

J. Place the 3/4" rigid conduit assembly onto the back frame of the sweep between the connecting

angle and connecting flange.

Figure 5AC

K. Fasten the junction boxes to the mounting plate using two (2) 3/8"-16 x 1-3/8" U-bolts, four (4) lock

washers and hex nuts.

Figure 5AD

Advertising