Start the auger – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-751-G2 User Manual

Page 59

Advertising
background image

6. Start-Up

PNEG-751-G2 12" Series II Sweep 131' and 135' Diameter

59

Start the Auger

A. Step on the foot switch and press the “Start” button.

B. Run the auger through a “break-in” period if it is being used for the first time or for the first time of

the season.

C. “Polish” the flighting by running the auger at partial capacity until it is smooth, before attempting

full capacity.

CAUTION

DO NOT start or stop the auger while it is under load.

CAUTION

Failures may occur if the auger is run full before it has been “polished” during
the “break-in” period.

CAUTION

NEVER operate the auger empty. Operating augers empty for any length of
time will cause excessive wear. NEVER operate the auger at speeds higher
than recommended.

CAUTION

Be aware of any unusual vibration or noises during the initial start-up and
“break-in” period. If anything unusual is detected, immediately shut down the
auger and disconnect and lock out the power supply before servicing.

Advertising