5. Assembly

PNEG-751-G2 12" Series II Sweep 131' and 135' Diameter

45

L. Attach the 3/4" rigid conduit assembly to the sweep using the 5/16"-18 x 3/4" studs welded to the

sweep using 1" conduit clamps, lock washers and hex nuts.

M. Run the 14 AWG stranded wires into the drive motor and fasten the 3/4" x 48" liquid-tight flex conduit

to the motor using one 3/4" liquid-tight flex conduit coupling. Some motors may require a reducer
bushing not supplied with the sweep. Connect the leads as required.

Figure 5AE

N. Run the 10 AWG stranded wires into the auger motor and fasten the 3/4" x 40" liquid-tight flex

conduit to the motor using one 3/4" liquid-tight flex conduit coupling. Some motors may require a
reducer bushing not supplied with the sweep. Connect the leads as required.