Command set – Advantech Data Acquisition Modules ADAM 4000 User Manual

Page 109

Advertising
background image

Command Set


4-6 ADAM 4000 Series User’s Manual

ADAM-4011D Command Table

Command Syntax

Command Name

Command Description

Page No.

%AANNTTCCFF

Configuration

Sets the address, input range,baud
rate, data format, checksum
status, and/or integration time for a
specified analog input module

5-4

$AA2

Configuration Status

Returns the configuration
parameters for the specified
analog input module

5-10

$AAF Read

Firmware

Version

Return the firmware version code
from the specified analog input
module

5-12

$AAM

Read Module Name

Return the module name from the
specified analog input module

5-13

#AA

Analog Data In

Returns the input value from a
specified analog input module in
the currently configured data
format

5-14

$AA0

Span Calibration

Calibrates an analog input module
to correct for gain errors

5-19

$AA1

Offset Calibration

Calibrates an analog input module
to correct for offset errors

5-20

#** Synchronized

Sampling

Orders all analog input modules to
sample their input values and store
them in special registers

5-21

$AA4 Read

Synchronized

Data

Returns the value that was stored
in the specified module's register
after the #** command

5-22

$AAB Open

Thermocouple

Detection

Ask the module to respond
whether the thermocouple is open
or not

5-24

$AA3

CJC Status

Returns the value of the CJC
sensor for a specified analog input
module

5-25

$AA9SNNNN CJC

Offset

Calibration

Calibrates the CJC sensor for
offset errors

5-26

(Continued on following page)

Advertising