4018M
@AAL
Name
Event Record Count command
Description
Request the number of event records stored in the analog
input data logger at address AA.
Syntax
@AAL (cr)
@
is a delimiter character.
AA
(range 00-FF) represents the 2-character hexadecimal
address of an analog input data logger.
L
is the Event Record Count command.
(cr)
is the terminating character, carriage return (0Dh).
Response
!AAHHHH(cr)
if the command is valid.
!
is a delimiter character indicating a valid command was
received.
AA
(range 00-FF) represents the 2-character hexadecimal
address of an analog input module.
HHHH
represents the 4-character hexadecimal number of
event records stored in the analog input data logger at
address AA.
(cr)
is the terminating character, carriage return (0Dh).
Example
command: @F3L(cr)
response: !F30096(cr)
The command requests the number of event records stored
in the analog input data logger at address F3.
The module currently has 150 event records.