Data Formats and I/O Ranges

B-10 ADAM 4000 Series User’s Manual



Range
Code
(hex)

Input Range
Description

Data Formats

Maximum
Specitied
Signal

Minimum
Specitied
Signal

Displayed
Resolution

29

100.00 Ω
Nickel RTD
α = .00392
0°C to 100°C

Engineering
Units

+100.00 +000.00 0.01°C

% of FSR

+100.00

+000.00

0.01%

Twos
Complement

7FFF 0000 1

LSB*

Ohms +200.64

+120.00

10

mΩ


NOTE:

* Resolution is one LSB of 16 bits